厭氧低溫實驗箱
●奇特的門鎖設計,裝備電子鎖功用,操作利便,密封性好。
●奇特的三層箱體構造,能疾速降溫。
●箱內送風體例采取加長軸風機直吹送風體例,平均度好。
●箱體氣路體系,電氣體系,分體式規劃,平安性好。
●內箱材料采取SUS304不鏽鋼;外箱材料采取雙靣鍍鋅鋼板,概況靜電噴塑處置。
●箱體降溫體系、電控體系已模塊化,且分隔規劃,平安牢靠。
●奇特的氣路設計,確保疾速降溫下降濃度,而且連結低氧氣濃度。
效勞熱線:020-28608023
- 技術槼格
- 制冷體系
- 掌握六开彩开奖今晚结果體系
- 規範設置裝備擺設
- 選購配件
型號Model | AT91-200 | AT216-200 | AT512-200 | AT1000-200 | AT91-300 | AT216-300 | AT512-300 | AT1000-300 | ||
內容積(L)Internal Volume (L) | 91 | 216 | 512 | 1000 | 91 | 216 | 512 | 1000 | ||
內箱尺寸(mm) Inner Dimension (mm) | W | 450 | 600 | 800 | 1000 | 450 | 600 | 800 | 1000 | |
H | 450 | 600 | 800 | 1000 | 450 | 600 | 800 | 1000 | ||
D | 450 | 600 | 800 | 1000 | 450 | 600 | 800 | 1000 | ||
外箱尺寸(mm) Outer Dimension (mm) | W | 1060 | 1210 | 1500 | 1730 | 1060 | 1210 | 1500 | 1730 | |
H | 820 | 970 | 1210 | 1480 | 820 | 970 | 1210 | 1480 | ||
D | 635 | 785 | 1065 | 1270 | 635 | 785 | 1065 | 1270 | ||
溫度局限(℃)Temperature Range (℃) | (環溫+20~200)℃ (Ambient temperature +20~200)℃ | (環溫+20~300)℃ (Ambient temperature +20~300)℃ | ||||||||
陞溫時候(min) Temperature Rise and Time(min) | (環溫+20~200)℃ (Ambient temperature +20~200)℃ | (環溫+20~300)℃ (Ambient temperature +20~300)℃ | ||||||||
≤40/min | ≤60/min | ≤70/min | ||||||||
箱內殘畱氧氣濃度≤100ppm,耗高純度惰性氣體(如:N2)流量 Residual oxygen concentration ≤100ppm, consumption flow of high-purity inert gas (such as: N2) | ≤20L/min (≤50min fall ) | ≤50L/min (≤50min fall ) | ≤100L/min (≤50min fall ) | ≤200L/min (≤50min fall ) | ||||||
≤7L/min(濃度連結) ≤7L/min (concentration maintaining) | ≤15L/min(濃度連結) ≤15L/min (concentration maintaining) | ≤30L/min(濃度連結) ≤30L/min (concentration maintaining) | ≤60L/min(濃度連結) ≤60L/min (concentration maintaining) | |||||||
調溫體例 Temperature Regulation Mode | 強迫送風輪回換熱體例+外部冷卻體系 Forced air circulation heat transfer mode & internal cooling system | |||||||||
運用情況Operating Environment | 溫度:(5~36)℃ 濕度:(30~85)%RH 氣壓:(86~106)kpa Temperature: (5~36)℃ Humidity: (30~85)%RH Pressure: (86~106) kPa | |||||||||
材料Material | 內箱Inner Chamber | 不鏽鋼板 SUS304 Stainless steel sheet SS304 | ||||||||
外箱Outer Chamber | 雙靣鍍鋅鋼板,概況處置後靜電噴塑處置 Two-sided galvanved plafe- with electrostatic powder coating | |||||||||
保溫Thermal Insulation | 纖維低溫棉 High-temperature fiber cotton | |||||||||
箱門密封條 Chamber Door Sealing Strip | 耐低溫密封條(不含矽) High temperature resistant sealing strip (exclusive of silicon) | |||||||||
執行器Actuator | 風機Fan | 加長軸風機 Extended shaft fan | ||||||||
風門Damper | 手動調理換氣+輪回 Manual adjustment for ventilation & circulation | |||||||||
加熱器Heater | 出口鎳鉻郃金電發燒絲 Imported nickel-chrome electric heater wire | |||||||||
掌握器 體系 Controller System | 顯示屏+PLCTouch Screen & PLC | 7.0",800×480分辯率,夾雜輸入PLC 7.0", 800×480 resolution, mixed output PLC | ||||||||
運轉體例Running Mode | 程式運轉(輸出的溫度和濕度法式運轉) Program runs in Auto mode ( An entered temperature & humidity program is run) | |||||||||
設定體例Setting Mode | 簡體中文+英文,觸摸輸出 Simplified Chinese & English, input by touch | |||||||||
顯示分辯率Display Resolution | 溫度:0.1℃,時候:s Temperature: 0.01℃, pressure: 0.01kPa, time: s | |||||||||
傳感器Sensor | PT100(鉑電阻) ,K型熱電偶 PT100 (platinum resistor),K-type thermocouple | |||||||||
掌握體例Control Mode | 抗積分飽和PID+自整定 Anti-integral saturation PID & auto-tuning | |||||||||
通信功用Communication Function | (選購功用)RS485,利便近程和當地通信監控,(需配監控軟件,RS485/RS232轉換器,需用到PC機COM,USB口各1個),同時最多可接16台,線材最長700m (Optional) RS485 makes it convenient for remote and local communication monitoring (monitoring software is required; RS485/RS232 converter, one PC computer COM and one USB port are required). Meanwhile, maximum 16 sets can be connected, the maximum length of wire material is 700m. | |||||||||
附加功用Additional Function | 毛病報警提醒功用,高低限庇護功用 Fault alarm prompt function, upper and lower limit protection function | |||||||||
電源(V)Power Supply(V) | 交換電壓380V±38V 頻率50Hz±0.5Hz 三相四線+接地庇護 AC voltage 380V±38V Frequency 50Hz±0.5Hz 3-phase 4-wire & earthing protection | |||||||||
最大電流(A) Maximum Current (A) | 3 | 4 | 7.6 | 9.8 | 4.1 | 5.8 | 9.8 | 14.5 | ||
電源功率(kW)Power (kW) | 2 | 2.7 | 5 | 6.5 | 2.7 | 3.8 | 6.5 | 9.5 | ||
分量(kg)Weight (kg) | 120 | 160 | 280 | 460 | 120 | 160 | 280 | 460 | ||
規範設置裝備擺設Standard Configuration | 樣品架2套,腳輪4個,保險絲4個氧氣濃度剖析儀1套,流量計3個,減壓閥2個,風機變速器1個 2 sets of sample holders, 4 casters, 4 fuses, 1 set of oxygen concentration analyzer, 3 flow meters, 2 pressure relief valve, 1 fan speed transmission | |||||||||
平安裝配Safety Device | 漏電開關,機電,相序,超溫等庇護功用 Leakage switch, motor, phase sequence, over-temperature protection ,etc. | |||||||||
注:氮氣進氣壓力和空氣進氣壓力都為1kgf/cm²。 Note: Both the nitrogen inlet pressure and air inlet pressure are 1kgf/cm². |
●奇特的門鎖設計,裝備電子鎖功用,操作利便,密封性好。
●奇特的三層箱體構造,能疾速降溫。
●箱內送風體例采取加長軸風機直吹送風體例,平均度好。
●箱體氣路體系,電氣體系,分體式規劃,平安性好。
●內箱材料采取SUS304不鏽鋼;外箱材料采取雙靣鍍鋅鋼板,概況靜電噴塑處置。
●箱體降溫體系、電控體系已模塊化,且分隔規劃,平安牢靠。
●奇特的氣路設計,確保疾速降溫下降濃度,而且連結低氧氣濃度。
Topect觸摸式溫濕度掌握香巷六给彩开奖结果2021年器是大冷王公司針對情況設備行業開辟;它由觸摸屏、PLC、溫度模塊和濕度模塊構成,功用壯大。觸摸屏自帶可眎編纂軟件、PLC邏輯編程、可擴大輸出輸入口、可擴大多點溫度;具有USB接口,可以導出數據(時候可選),可經過RS485通信與PC銜接完成近程監控。
●本公司自行研發高機能掌握器,65536色7",TFT真彩觸摸屏,800×480點陣,確保顯示結果真,操作溫馨,全部界靣作風簡約清楚,操作利便,運轉牢靠。
●掌握用具有壯大的偵錯庇護功用,毛病報警及消除闡明;可擴大的輸出輸入口,可以根據請求編制分歧掌握法式來完成分歧的功用;針對各類情況設備離別開辟,可壹致用軟件集中電腦掌握,掌握器界靣作風分歧,利便用戶操作。
●采取PLC法式掌握,具有守時運轉、住手功用,斷電庇護功用,穩固性好。
●可接集中監控軟件,且供給通信協定,便於用戶停止二次開辟;可近程監控多台實驗箱。
●溫度、氧氣濃度紀錄儀(圖1)。
●近程掌握及數據傳輸用通信接口和軟件(圖2)。
●氧氣濃度剖析儀(圖3)。
●金屬過濾器。
●枯燥過濾器。
●公用承重型樣品架。
●輪回風機可調速。
●非標定制設備可以知足六开彩开奖今晚结果用戶需求。